Chillers and Coolers

Air Cooled Chilllers

Water Cooled Chillers

Dry coolers 

Centrifygal Chillers

Fan Coil Units

 

Air Cooled Chillers   

              

30XA

 

  • Twenty sizes with nominal cooling capacities from 270 to 1700 kW.
  • The ideal solution for industrial and commercial applications with optimal performances and maximum quality.
  • Available in two versions: one with extremely low noise levels and superior energy efficiency; the other with unequalled energy efficiency for minimised operating costs.
  • Twin-rotor screw compressors with high-efficiency motor and a variable capacity slide valve.
  • All aluminium micro-channel heat exchanger (MCHX) with increased corrosion resistance and higher efficiency than a copper/aluminium coil.
  • Use of R134a refrigerant with zero ozone depletion potential - the microchannel heat exchangers reduce the refrigerant charge by 30%.
  • Low-noise 4th generation Flying Bird fans made of composite material.
  • Touch-screen Pro-Dialog control system.
  • Flooded multi-tube evaporator.
  • Economizer system with electronic expansion device for increased cooling capacity.
  • V-shape condenser coils allow quieter air flow across the coil.
  • Simplified electrical connections.
  • Units are run-tested before shipment and include a quick-test function for fast commissioning.
  • Leak-tight refrigerant circuit.
  • Comprehensive endurance tests.
  • Multiple remote control, monitoring and diagnostic facilities.

 

30RB

 

 

  • Twelve sizes with nominal cooling capacities from 260 to 760 kW.
  • State-of-the-art Aquasnap Puron liquid chillers operatie on the ozone-friendly refrigerant R410A.
  • All-aluminium micro-channel condenser (MCHX) for extra efficiency.
  • Integrated hydronic module (option) with water pump and expansion tank.
  • Low-noise scroll compressors with low vibration levels.
  • V-shaped condenser coils, allowing quieter air flow across the coil.
  • Low-noise 4th generation Flying Bird fans. Rigid fan installation prevents start-up noise.
  • Simplified electrical connections.
  • Fast commissioning, as all units are systematically run tested before shipment.
  • Economical operation with increased energy efficiency at part load and dynamic superheat management.
  • Leak-tight refrigerant circuit and reduced maintenance costs.
  • Auto-adaptive control algorithm and automatic compressor unloading for increased reliability.
  • Exceptional endurance tests.

 

 

 

   

 

30RB/RQ

  

  • Four sizes with nominal cooling capacities from 17 to 33 kW and heating from 17 to 33 kW.
  • Optional, Integrated hydronic module.
  • Ozone-friendly refrigerant HFC-410A.
  • Low-noise, twin-speed axial fans, supported by an extremely rigid chassis.
  • Quiet, vibration-free scroll compressors, durable and maintenance-free.
  • Welded, stainless steel plate heat exchanger evaporator.
  • Refrigerant circuit is leak-proof for life. Pressure sensors replace pressure switches and capillary tubes.
  • Units include a main switch, and a single entry power supply point.
  • Autoadaptive microprocessor control.
  • Class A energy efficiency ratings.
   

 

Water Cooled Chillers 

 

16TJ 16N

 

Fifteen sizes with nominal cooling capacities from 352 to 2461 kW.

• Designed for cooling applications where low-pressure steam is available as waste heat.

• Can tie into district steam systems.

• Allows diversification of critical cooling requirements. Critical cooling loads are met with minimal electrical power input with steam-fired chillers.

• Allows use of smaller emergency generators since the electrical load associated with an absorption chiller is minimal, compared to an electrically driven chiller.

• Ozone-friendly and CFC-free. Cooling requirements are met without chlorine-based refrigerants.

• Minimises global warming effect by greatly reducing power consumption and eliminating the generation of greenhouse gases.

• Reduced noise and vibration levels. The absorption chiller does not use a large motor-compressor, leading to quiet, trouble-free operation.

• Small footprint. The high efficiency associated with these chillers results in a reduction of the required installation space.

• Auto-diagnosis system monitors operating conditions, predicts chiller information and maintains stable operation.

• Advanced high-precision control system.

• Absorption pump with inverter control (option) for energy-saving operation. • High-performance purge system maintains unit performance and minimises

maintenance requirements.

• State-of-the-art protection devices guarantee enhanced operating safety.
   

 

 

16LJ

 

Fifteen sizes with nominal cooling capacities from 264 to 1846 kW.

• Designed to provide chilled water from waste heat sources, generated from industrial processes and cogeneration systems.

• Allows diversification of critical cooling requirements. Critical cooling loads are met with minimal electrical power input with hot water-fired chillers.

• Allows use of smaller emergency generators since the electrical load associated with an absorption chiller is minimal, compared to an electrically driven chiller.

• Ozone-friendly and CFC-free. Cooling requirements are met without chlorine-based refrigerants.

• Minimises global warming effect by greatly reducing power consumption and eliminating the generation of greenhouse gases.

• Reduced noise and vibration levels. The absorption chiller does not use a large motor-compressor, leading to quiet, trouble-free operation.

• Small footprint. The high efficiency associated with these chillers results in a reduction of the required installation space.

• Auto-diagnosis system monitors operating conditions, predicts chiller information and maintains stable operation.

• Advanced high-precision control system.

• Absorption pump with inverter control (option) for energy-saving operation. • High-performance purge system maintains unit performance and minimises

maintenance requirements.

• State-of-the-art protection devices guarantee enhanced operating safety
   

 

  

16DJ

 

Twenty-three sizes with nominal cooling capacities from 352 to 5274 kW and

heating capacities from 268 to 4026 kW.

• The 16DJ absorption chillers/heaters offer building owners a better solution for

many new and retrofit applications. Installation of a direct-fired chiller/heater

eliminates the need for a boiler, reducing the initial cost of the system.

• Excellent for peak shaving during high electrical demand periods.

• Allows diversification of critical cooling requirements. Critical loads are met

with minimal electrical power input.

• Allows use of smaller emergency generators since the electrical load associated

with an absorption chiller is minimal.

• Ozone-friendly and CFC-free.

• Minimises global warming effect by greatly reducing power consumption.

• Reduced noise and vibration levels. The absorption chiller does not use a large

motor-compressor, leading to quiet, vibration-free operation.

• Small footprint. The high efficiency associated with double-effect chillers

results in reducing the required installation space.

   

 

 

 


 

Centrifugal Chillers

 

19XR

 

Nominal cooling capacities from 1000 to 5300 kW.

• Mix-match capabilities – a complete line of compressors and heat exchangers to ensure the optimal combination of machine components regardless of capacity, lift and efficiency specifications.

• Hermetic compressor – elimination of leak risks from the compressor/motor shaft sealing in an open compressor.

• Single-stage compressor with special features – aerodynamically contoured impellers, variable inlet guide vanes and movable diffusers for better product reliability and compressor part and full-load operating efficiency.

• Variable speed compressor capability – improvement of part load efficiency and electrical performance.

• Heat exchangers certified by the European pressure vessels code (PED).

• Carrier numerical product integrated control offers unmatched flexibility and functionality. Each unit integrates directly with the Carrier Comfort Network (CCN), providing a system solution to controls applications
   

 

 

30XW

 

 

  • Ten sizes with nominal cooling capacities from 476 to 1178 kW and nominal heating capacities from 506 to 1276 kW.
  • The ideal solution for industrial and commercial applications that require optimal performance and maximum quality.
  • Two versions: 30XW for air conditioning applications, and 30XWH for heating applications.
  • Two efficiency classes: the standard-efficiency 30XW offers a combination of performance and energy efficiency. The high-efficiency 30XW-P offers unequalled energy efficiency for reduced operating cost.
  • Twin-rotor screw compressors with high-efficiency motor and variable slide-valve capacity control to precisely match the cooling capacity to the load.
  • R134a refrigerant with zero ozone depletion potential.
  • Touch-screen Pro-Dialog control system.
  • Mechanically cleanable flooded shell and tube heat exchangers.
  • 30XWH range for heating applications with dedicated control algorithms for heating mode.
   

 


 

Dry Coolers

 

 

09GDV

 

  • 15 sizes with nominal capacities from 140 to 1442 kW for liquid use, and with nominal capacities from 170 to 1812 kW for condenser use (condenser capacity R404A/T 15K).
  • The 09GDV dry coolers and 09LDV air-cooled condensers are designed for commercial and industrial refrigeration plants.
  • The range is especially suitable when high capacity compared to available space, low noise level and low energy consumption are required.
  • Two fan sizes and five fan speed alternatives to reach the required sound level. The axial fans are equipped with squirrel-cage motors, built according to IEC standards with the IP54 protection and insulation class F. Motors are provided with shaft seals and drainage holes.
  • Casing made of hot-dip galvanized steel.
  • Complete fan control systems available, based on fan speed regulation (SVC) or on stepwise starting cycle of fans (step control).
  • Product selection using the Polar Power software performance data according to Eurovent rating standards 7/C/002/1999 and 7/C/003/1999.
  • The heat transfer section is made of copper tubes and aluminium fins, which cover the tubes totally. Fin spacing is 2.3 mm.
  • The heat transfer section can be multi-circuited or equipped with a sub-cooling circuit.
  • The fan chambers are separated laterally.
  • The units are equipped with lifting lugs, and the smaller models are suitable for lifting by a forkliftIR-C
  • Epoxy-coated aluminium fins available to extend the working life of the coil in urban and coastal climates.
  • Water-spraying system to increase the heat transfer capacity during short loading peaks.
  • Vibration dampers.
  • Star/delta connection
   

 

09GE

 

 

  • 16 condenser sizes with nominal cooling capacities from 68 to 1016 kW (R-404A), and 16 dry cooler sizes with nominal cooling capacities from 64 to 990 kW (water).
  • Air-cooled condensers, designed for refrigeration plants, where refrigerants such as R-404A, R-134a and R-407C are used.
  • 09GE dry coolers are suitable for cooling water or other fluids that do not corrode copper. The units can be applied to commercial and industrial refrigeration plants and to air conditioning cooling.
  • Low speed, low-noise options make the units particularly suitable for noise sensitive applications.
  • Two fan sizes and five fan speeds offer several sound level classes and energy-saving options.
  • Efficient axial fans, equipped with motors built to IEC standards.
  • Inherently reliable, sturdy corrosion-resistant construction.
  • Fully isolated heat transfer section.
  • Copper tube and aluminium fin heat transfer sections.
  • Water spray system (option) to increase condensing capacity.
  • Extra high legs and anti-vibration mounts available as accessories.
  • Automatic fan control systems available, based on fan speed control or on stepped fan starting cycle.
  • Performance values are to ENV 327 and ENV 1048 standards.
  • Two mounting positions are available: vertical air flow (V) and horizontal air flow (H).
  • Casing made of hot dip galvanised steel.
  • Selection using the Carrier electronic selection program
   

 

09GF

 

  • 39 condenser sizes with nominal capacities from 7.5 to 265 kW (R-404A) and 18 dry cooler sizes with nominal capacities from 9.8 to 187 kW (water).
  • Condensers are designed for refrigeration plants, where refrigerants such as R-404A, R-134a and R-407C are used.
  • Dry coolers are suitable for cooling water or other fluids that do not corrode copper.
  • Low noise levels mean units are suitable for sensitive applications, such as hospitals and offices.
  • Three fan sizes and four fan speeds offer several sound level classes.
  • Inherently reliable, sturdy corrosion-resistant construction.
  • Light weight, service valve and accessible connections facilitate installation.
  • Precise selection using the Carrier electronic selection program.
  • Units can be installed either horizontally or vertically.
  • Optional fan control systems available, based on infinitely variable fan speed control or stepped fan starting cycle.
  • Heat exchanger is made of copper tubes and aluminium fins.
  • Electrical connections include a safety switch.
   

 

 


 

Fan Coil Units

 

42DW

  • Available in four sizes with two-pipe, two-pipe plus electric heater or four-pipe coils, with an air flow range from 230 to 800 l/s, a cooling capacity range from 5.5 to 12.7 kW and a heating capacity range from 7.3 to 17.9 kW.
  • Compact ducted chilled-water fan coil units, designed for installation above false ceilings.
  • Reliable and efficient heating and cooling for light commercial and residential applications.
  • Minimised size, using a V-shaped coil, and reduced height of 285 mm.
  • Air return from the rear or below for increased installation flexibility.
  • Air outlet modularity (sleeve or spigots), outlets on the front or at the sides.
  • High-capacity unit with low sound levels.
  • Four-speed motor, offering a choice of two medium comfort speeds.
  • High-pressure centrifugal fans.
  • Compatible with the 35BD/SR air diffuser range.
  • Safe factory-installed electric heater for single or two-stage hot water heating.
  • Low hydraulic pressure drop with a valve mounted, compatible with all chiller pump kits.
  • Quick installation with factory-installed options (controls, valves).
  • Improved market competitiveness.

42EM

K
  • Eight sizes with two-pipe, two-pipe plus electric heater or four-pipe coils, with an air flow range from 66 to 259 l/s, a cooling capacity range from 1.26 to 7.26 kW and a heating capacity range from of 1.52 to 8.54 kW.
  • Decentralised compact ducted chilled-water fan coil system, designed for installation in plant rooms. This allows centralised service and maintenance.
  • Reliable and economical cooling and heating for light commercial and office applications.
  • Low height of 225 mm.
  • Installation flexibility with two versions: modular or compact.
  • Compatible with the 35BD/SR air diffuser range.
  • Air outlet modularity with different spigots.
  • Extremely low sound level in the ducting of the air distribution system.
  • Offered technologies:
    Multispeed AC motor: six-speed fan motor, offering a choice of several medium 
    comfort speeds.
    Variable EC motor: Low Energy Consumption option, high efficient, extend operating life and cost saving.
  • High-pressure centrifugal fans, compatible with all main air distribution systems.
  • High-efficiency EU3 filter.
  • Safe factory-installed electric heater for single or two-stage hot water heating.
  • Low hydraulic pressure drop with a valve mounted, compatible with all chiller pump kits.
  • Quick installation with factory-installed options (controls, valves).

42N_S

  • Four sizes with two-pipe, two-pipe changeover or two-pipe coils, with an air flow range from 35 to 333 l/s, a cooling capacity range from 0.8 to 5.5 kW, and a heating capacity range from 0.6 to 8.1 kW
  • Concealed or cabinet chilled-water fan coil system, designed for vertical and horizontal installation in a room or above a false ceiling
  • Units offer reliable, economical cooling and heating for hotels, light commercial and residential applications
  • Cabinet version complete with control terminal
  • Combines aesthetic slim-line design (depth only 220 mm) with high installation flexibility
  • Two fan types, a tangential fan for ultra-low noise level and a centrifugal fan for high air distribution system compatibility
  • Factory-mounted PTC electric heater with low and high capacity settings
  • Low hydraulic pressure drop with a valve mounted
  • Quick installation with factory-mounted options (controls, valves)
  • Improved market competitiveness

42GW

  • Six sizes with two-pipe, two-pipe plus electric heater or four-pipe coils, with an air flow range from 100 to 470 l/s, a cooling capacity range from 1.5 to 11 kW, and a heating capacity range from 2 to 14 kW.
  • Cassette chilled-water fan coil system designed for installation in false ceilings with an all-in-one air distribution grille integrated in the ceiling panel.
  • Reliable and economical cooling and heating for light commercial applications, large offices, shops, restaurants, showrooms, lobbies and meeting rooms.
  • Elegant air inlet grille, blends in with any room décor.
  • Minimised size, using a U-shape coil, and low height of 300 mm.
  • All-in-one design for increased installation flexibility.
  • Two-, three- or four-way air outlets permit adjustable Coanda effect air diffusion to suit individual comfort requirements.
  • Low sound level.
  • Safe factory-installed electric heater for single or two-stage hot water heating.
  • Low hydraulic pressure drop, compatible with all chiller pump kits.
  • Easy maintenance with direct access from below to all main components.